PP2000T cryo preparation chamber

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • PP2000T cryo preparation chamber
  • PP2000T cryo preparation chamber
  • Typical installation (with on-column SEM cooling dewar)
  • PP2000T Off-Column Turbomolecular Pumping System with connecting stainless steel bellows
  • PP2000T Off-Column Turbomolecular Pumping System. The high mass steel base ensures elimination of vibration
  • Transfer rod tip and specimen shuttle
  • Standard liquid nitrogen ‘slushing’ system
  • PP7465 Advanced Specimen Handling System
  • The PP7465 allows pre-frozen specimens to be handled with ease
  • Plunge freezing and transfer
  • Operator’s view during transfer into the preparation chamber cold stage
  • View though front window, showing cold stage, cold fracturing knife and cooled specimen probe
  • Low energy ‘cool’ sputter coating head
  • PP2000T gas-cooled cold stage, range: down to -192°C
  • PP2000T gas-cooled cold trap (modified for cryo-DualBeam), range: down to -192°C
  • SEM cold trap running at -192°C. This allows very low SEM stage temperatures to be used without the risk of specimen contamination
  • On-column SEM cooling dewar
  • Off-column SEM cooling dewar with all-day holding time

PP2000 and PP2000T Cryo-SEM Preparation Systems

Quick Overview

The PP2000 and PP2000T are column-mounted, gas-cooled cryo preparation systems suitable for most makes and models of SEM, FE-SEM and FIB/SEM. Both systems include all the facilities needed to rapidly freeze and transfer specimens. The column cryo preparation chamber includes tools for cold fracturing, controlled sublimation and specimen coating. The specimen can then be transferred onto a highly stable SEM cold stage for observation. Cold trapping in the cryo preparation chamber and SEM chamber ensures the whole process is frost free.

Key features

  • * Market leading cryo-SEM - worldwide references on all major current SEMs
  • * Column-mounted cryo preparation chamber - essential for frost-free transfer
  • * Gas-cooled SEM cold stage and cold trap - very low temperatures (-192°C); not possible with conduction cooling
  • * Gas cooling - rapid temperature change allowing sublimation on the SEM stage; not possible with conduction cooling where cool-down times are too slow
  • * Off-column SEM cooling dewar option (CHE2000) with all-day run time - only one fill per day
  • * Highest levels of vibration isolation
  • * Comprehensive cold trapping throughout the system
  • * High resolution sputter coating (platinum (Pt) or iridium (Ir) recommended)
  • * PP7465 Advanced Specimen Handling System - allows pre-frozen specimens to be manipulated under LN2 and transferred into the PP2000/PP2000T under vacuum
  • * Turbo pumping system mounted off-column - less mass on the SEM
  • * Three-year warranty

For information on the PP2000/PP2000T and the cryo-SEM technique, visit our Preparation Techniques and Advantages page.

To view cryo-SEM images, visit our Image Gallery.

To search for and buy accessories for this product, visit our Shop.

Product Description


The PP2000 cryo-SEM series embodies design features that ensure the vacuum in all three areas is optimally clean and that specimens risk minimal exposure to contamination. The PP2000 cryo-SEM series is the result of many years’ experience of cryo techniques and vacuum and coating technologies. The instrumentation is ‘logical’, easy to understand, simple to use and maintain, and will give high quality results from a wide range of specimens.

Specimen handling, mounting and freezing
We offer a wide range of holders to suit most specimen types and can tailor holders to specific customer requirements. The standard slushy nitrogen freezer is suitable for most bulk SEM specimens. For handling pre-frozen specimens, the optional PP7465 Advanced Specimen Handling System allows specimens that have been frozen by alternative freezing methods (or stored field specimens) to be manipulated under liquid nitrogen and then transferred under vacuum into the PP2000/PP2000T preparation chamber for subsequent processing and observation.

Specimen freezing and manipulation of pre-frozen specimens
Specimen transfer: The transfer device is used to transfer frozen specimens under vacuum between the freezing device, preparation chamber and SEM cold stage. The compact, vacuum-tight design and ease of use of the PP2000/PP2000T transfer device is crucial to the success of the cryo preparation procedure. A bayonet connection to the specimen shuttle helps to ensure rapid transfer.

PP7465 Advanced Specimen Handling System option: The PP7465 allows pre-frozen specimens to be efficiently and easily transferred into the PP2000/PP2000T for subsequent processing (fracturing, sublimation, coating etc) and observation in the SEM or FIB/SEM.

Cryo preparation chamber and pumping
The PP2000T preparation chamber is attached directly to the microscope and provides preparation facilities needed for all types of specimens.

Cold stage and cold trapping: The chamber is a totally enclosed vacuum environment with integral gate valves to ensure stable, contamination-free operation. A variable temperature cold stage is mounted centrally in the chamber. Cooling is by copper conduction from an integral LN2 dewar. The specimen stage can be cooled to below -185°C and heated to 50°C, and controlled within an accuracy of +/- 1°C. The preparation chamber is fitted with large cold traps running at close to liquid nitrogen temperature. Additionally, the inner face of the cooling dewar acts as a very efficient cold trap. Controls for specimen exchange are conveniently located on the preparation chamber, making specimen change simple, fast and reliable.

Sputter coating: A compact, low-energy sputter coater is fitted enabling high-resolution coating of platinum (Pt) (standard in the PP2000T) and other metals, including gold/palladium (Au/Pd) and iridium (Ir). Argon gas used in the sputtering process can be provided by a small cylinder of ultra-high purity (PP2000T). For non-high resolution applications standard grade argon from a cylinder can be used (PP2000). A carbon fibre evaporation head is available as an option.

High vacuum environment: The PP2000T preparation chamber is pumped by a remotely-positioned turbomolecular pumping system, conveniently located on the floor behind the SEM. Typical preparation chamber vacuums during operation are in the region of 10-5mbar or better. Positioning the turbomolecular pump away from the SEM ensures total elimination of mechanical vibration. It also means that the mass and size of the preparation chamber is kept to a minimum. The PP2000 rotary pumped model will typically operate at vacuums in the region of between 10-2mbar and 10-3mbar when cold.

Specimen manipulation and observation: A micrometer-controlled, cooled fracturing knife and cooled probe (‘wobble-stick’) allows cold specimens to be cut, fractured and manipulated. The PP2000/PP2000T preparation chamber includes a large viewing window and internal LED lighting. An optional stereo microscope (PP7424) with 10x or 20x magnification can be fitted.

SEM cold stage and cold trap (anti-contaminator): The PP2000/PP2000T cold stage attaches to the SEM stage, introducing a cold block for low temperature observation. Cooling of the stage is by pre-cooled nitrogen gas. An important and unique feature of the PP2000T/PP2000 SEM dewar system is that the SEM stage and cold trap are cooled by two separate cold gas circuits - both capable of reaching temperatures down to -192°C . This configuration means that the user can easily set up a large temperature difference between the SEM stage and the anti-contaminator, typically in the region of 40-50°C, without compromising the stability of the SEM stage.

SEM cold stage and cold trap cooling dewar: There is a choice of a small (0.6L) SEM column-mounted dewar, or large (12L) off-column dewar - the CHE2000. This is highly recommended as it will run for over nine hours without needing to be refilled and includes a pre-cooling system that allows lower grade nitrogen gas to be used, plus a heater to prevent build up of ice on the top of the dewar. The CHE2000 is typically seated behind the SEM, alongside the turbomolecular pumping system and rotary pump.


Site Requirements


NB: Site requirements will vary according to the PP2000/PP2000T package supplied. The information below is only an indication of the services required - for full Site Requirement document please contact a member of our Sales team.

Mains electricity: Ensure that a suitable mains electricity supply (110 VAC or 240 VAC, frequency 50/60Hz) is available. Check that the voltage label attached to the side of the cabinet is suitable for the local voltage and frequency. A complete PP2000/PP2000T installation will require four separate mains power outlets of 10A (240V) and 20A (110V). If the optional CHE2000 off-column dewar and/or PP7690 Film Thickness Monitor accessory is fitted, additional mains power outlets will be required. NB: PP7690 may be powered from integral interlocked output on PP7480 Control unit rear panel. Mains supply should be on a separate circuit from the SEM.

Gases: The following gas supplies are required:

Nitrogen gas - Two 250 cubic foot cylinders of dry nitrogen gas (one of which should ideally be ZERO grade <3 vpm H2O) with regulators, to operate in the pressure range 0-15psi (0-1kg/cm-2, 0-1 bar). The first cylinder is required for the intermittent venting and slushing functions. The second cylinder is required for cooling the SEM stage and SEM anticontaminator. NB: if the CHE2000 off-column cooling dewar is fitted, lower grade nitrogen gas can be used.

Argon gas for sputter coating - For PP2000: One 250 cubic foot cylinder of dry argon gas (ZERO grade) with regulator, to operate in the pressure range 0-15psi (0-1kg/cm-2, 0-1 bar). For PP2000T: The system is supplied with a 1L canister of spectrographically pure argon sputtering gas, mounted directly onto the preparation chamber. This should be used for high-resolution applications.

Liquid nitrogen - During normal operation the PP2000/PP2000T will use around 12L of liquid nitrogen during a full working day. It is convenient to have a bulk storage dewar of liquid nitrogen which can be used to fill 1L/5L dewar containers for subsequently filling both dewars on the PP2000/PP2000T and the liquid nitrogen slushing chamber. The room in which liquid nitrogen is being handled or used needs to be well vented in accordance with local regulations. Suitable face masks and protective gloves are required.





Additional Information

Specifications
PP2000 and PP2000T Fitted as standard?

Cryo preparation chamber (column-mounted). Consisting of:
Built-in liquid nitrogen cooling dewar Yes
Two integral gate valves (loading and SEM) with appropriate electrical interlocks Yes
Variable temperature conduction cooled specimen stage (PP2000T: -185°C to 50°C) Yes
Large anti-contaminator plates above and below cold stage Yes
Micrometer-fed fracturing knife (cooled) Yes
Strong surface probe (cooled) Yes
High resolution sputter coater with target - PP2000: gold/palladium (Au/Pd), PP2000T: platinum (Pt) Yes
High purity argon supply (1L) PP2000T only
Carbon fibre evaporation head and power supply Option
Vacuum transfer device Yes
Internal LED illumination (two) Yes

Pumping system and controls
Anti-vibration block with solenoid-controlled pump and vent valves, vacuum tubing PP2000 only
Turbomolecular pumping system mounted on an anti-vibration trolley, connecting stainless steel bellows, high and low vacuum gauging, vacuum controller PP2000T only
Control unit for vacuum and temperature, HT and LT power supplies and gauges, SEM safety interlock Yes
Nitrogen gas control unit for separate monitoring and control of SEM stage and anti-contaminator Yes

SEM cooling dewar, SEM cold stage and cold trap (anticontaminator)
Gas-cooled nitrogen cold stage assembly (-192°C to 50°C) Yes
SEM chamber anti-contaminator (cooled and controlled separately from SEM stage). Temperature range: down to -192°C. SEM lamp Yes
Column mounted stainless steel SEM dewar (0.6L) with separate gas cooling circuits for SEM stage and SEM anti-contaminator Yes
CHE2000 12L capacity, off-column cooling dewar with + eight-hour run time, with separate gas cooling circuits for SEM stage and SEM anti-contaminator Option (highly recommended)

Specimen handling, freezing, specimen holders
Nitrogen slushing chamber mounted into instrument trolley desk-top Yes
PP7465 Advanced Specimen Handling System (for transferring pre-frozen specimens into the PP2000/PP2000T) Option
Instrument trolley with desk-top and adjustable lamp Yes
Specimen shuttles (x2) and stubs: two E7449 multi-specimen stubs and E7402 blank aluminum (Al) stubs (pack of 10) Yes
Comprehensive start-up kit with key spares Yes
Three-year warranty Yes

Some options and accessories (see Ordering Information for full list)
Terminating film thickness monitor and crystal holder Option
Long working distance stereo microscope (10x and 20x magnification) Option
Self-pressurising LN2 dewar and regulator (for LN2 storage and venting) Option
Carbon fibre evaporation head Option
Rock breaking stage for preparation chamber Option
Ordering Information NB: For a full quotation, including on-site installation and customer training, please visit the Contact Us section to get in touch with a member of our UK Sales team, or one of our global distributors.

PP2000 Cryo-SEM Preparation System for tungsten SEM applications, with column-mounted, rotary-pumped cryo-preparation chamber
PP2000T Cryo-SEM Preparation System for FE-SEM and DualBeam applications with high vacuum, turbo-pumped, column-mounted, cryo-preparation chamber
Pumping The PP2000 requires two 90L/m rotary pumps. The PP2000T requires one 50L/m rotary and one 90L/m rotary pump
EK3175 RV3 50 L/m 115/230V 50/60Hz vacuum pump + oil mist filter
EK3180 RV5 90 L/m 115/230V 50/60Hz vacuum pump + oil mist filter

Options and accessories
CHE2000 12L capacity off-column SEM stage and SEM cold trap cooling dewar. Replaces the standard 0.6L on-column dewar and gives a typical run time between fills of over nine hours
PP7465 Advanced dual slusher specimen handling system for transferring pre-frozen specimens
PP7450 Pressurised dewar (30L) for LN2 storage and venting gas supply
PP7416 Carbon fibre evaporation head
PP7424 Stereo microscope and mounting kit (X10/X20)
PP7690 Film Thickness Monitor, oscillator and crystal holder

Specimen holders and specimen shuttles
E7430 Baltec planchette holder shuttle (for use with PP7465)
E7432 Rivet holder shuttle - vice style (for use with PP7465)
E7433 Rivet holder stub - screw down style (for use with E7431)
E7449 Universal specimen stubs with surface holes and slots (pack of 5)
E7401 Specimen stub shuttle (spare)
E7402 Aluminum (Al) stubs (pack of 10)
E7403 Copper (Cu) stubs (pack of 10)
E7404 Clamping stub for tube fracture
E7405 Screw down stubs for thin specimens
E7406 Copper (Cu) stubs with 3 x 3mm slots (pack of 5)
E7407 Copper (Cu) stubs with 1 x 3mm slot (pack of 5)
32816510 Brass rivets for fracturing liquids (pack of 100)

Sputtering targets and carbon accessories
E7400-314A Gold (Au) target 0.008” thick
E7400-314C Platinum (Pt) target 0.008” thick
E7400-314IR Iridium (Ir) target 0.008” thick
A0819 Carbon fibre cord - high purity - 1m
A0819-5 Carbon fibre cord - high purity - 5m
Downloads PP2000 and PP2000T one-year service contact (PDF)